Skin Resurfacing Fractional Co2 Laser Equipment is a brand new laser rejuvenation technology. It fires a laser beam which is then split into numbers of microscopic beams, producing tiny dot to peel skin and penetrate the laser beam into the corium.
Skin Resurfacing Fractional Co2 Laser Equipment
Theory
Skin Resurfacing Fractional Co2 Laser Equipment is a brand new laser rejuvenation technology. It fires a laser beam which is then split into numbers of microscopic beams, producing tiny dot to peel skin and penetrate the laser beam into the corium. The adjustable Fractional CO2 Laser System fires a laser beam which is split into numbers of microscopic beams, producing tiny dot or fractional treatment zones within the selected target area only. Therefore, the heat of laser only passes deeply through the fractional damaged area. This allows the skin to heal much faster than if the whole area was treated. During the skin self-resurfacing, a great amount of collagen is produced for skin rejuvenation, eventually the skin will look much healthier and younger!
Handpiece details
Key point 1:
2 types inner tube choice:
More than 8 years lifespan USACoherent RF tube,
More than 3 years lifespan USA Glass tube
Energy test can penetrate 10pcs papaers
Key point 2:
7-jointed arm light conduct: use Smallest motor in the world,faster response by 0.3ms
Key point 3:
Strictly meet more widely patients’ different treatment area requirements:
Free graphic+ more than 20 types output patterns+
Each pattern can add hollow in the middle,
prevent the unwanted skin area from unnecessary treatment
Key point 4:
Multi-functional heads to reach comprehensive functions:
Scan head + Ultra pulsed head + Gynecology head + Andriatry head
Key point 5:
USA smoking purifying system:
eliminatesthe harmful smoking during treatment
USA smoking purifying system:
eliminatesthe harmful smoking during treatment
Specification
Display |
8.4 / 10.4 /15 inch LCD real color touch screen |
Light conducting system |
7 jointed arms to conduct light |
Wavelength |
10.6µm |
Tube Type |
USA RF tube/ Glass tube |
Power |
30W |
Mode |
Fractional / Normal / Vaginal |
Laser energy |
1-30W / 10-1000mj |
Figure option |
Free graphic, Square, Triangle, Round, Rectangle, Line, Hexagon, etc. |
Scan pattern size |
0.1x0.1mm—20x20mm |
Scan mode |
Sequence, random, mid split |
Dot quantity |
2500 dots at most |
Spot distance |
0.1-2mm |
Pulse energy |
10mj to 1000mj is optional for each dot. |
Times of scanning |
1-20 times |
Condenser focus |
f=50mm |
Spot size |
≤0.2mm at the focus |
Radiation time / Interval time |
0.01 1 s |
Aiming beam |
635nm infrared ray |
Power supply |
110/230V±10%, 60/50HZ |